Product Overview

The MC-500L (three-phase) fully automatic capacitance and inductance tester was specifically developed to address the challenges encountered when measuring the capacitance of individual capacitors in shunt capacitor banks at substation sites. It focuses on resolving the following issues:

(1) On-site measurement of individual capacitors requires disconnecting the connecting leads, which is not only labor-intensive but also increases the risk of damaging the capacitors.

(2) Low output voltage from the capacitance meter results in a low fault detection rate.

(3) Measure the inductance of the reactor.

This instrument features low measurement workload, quick and simple operation, stable performance, high measurement accuracy, and a high fault detection rate. In addition, its current measurement unit can also be used for measuring electrical equipment such as CVTs and surge arresters, thereby achieving multi-functionality in a single device.

Product Features

This eliminates the tedious procedures of repeatedly disconnecting and reconnecting wires, enabling the measurement of single-phase capacitance in grouped shunt capacitors as well as three-phase capacitors with various connection configurations, while also allowing the measurement of inductance in a wide range of reactors.

1. Without disconnecting the leads, rapidly measure the reactance values of three-phase capacitors and reactors simultaneously; regardless of Y, Y0, or Δ connection configurations, the system automatically converts these measurements into per-phase capacitance and total capacitance.

2. Without disconnecting the wiring, rapidly measure the capacitance and discharge resistance of individual capacitors in a shunt capacitor bank.
3. Do not damage the capacitor bushings; not only is the workload substantial, but the capacitors are also prone to damage.
4. On-site, non-disassembly measurement of the inductance and reactance of reactors
5. Low output voltage of the capacitance meter results in a low fault detection rate.
6. Automatic range switching;
7. Stores 7,168 test data points;
8. Large-screen LCD display (320×240 LCD) with Chinese character menu prompts;
9. Enable simultaneous on-screen display of waveforms and measurement data, making the testing process more intuitive.
10. Equipped with setting, calibration, and debugging functions.

Technical Specifications

1. Capacitance range: 0.2 μF to 2,000 μF

2. Capacity range: 5 to 20,000 kvar, with automatic calculation

3. Capacitance measurement accuracy:

  • ±1% of reading ±0.02 μF, when 0.2 μF to 2 μF
  • ±1% of reading ±2 digits, when 2 μF to 2,000 μF

4. Inductance range: 1 mH to 9.99 H

5. Inductance measurement accuracy: ±1.5% of reading ± 2 digits

6. Output voltage: AC 26 V / 500 VA; 50 Hz

7. Display Mode: Large-screen LCD display with full-Chinese character output, ensuring clear visibility both during the day and at night; Chinese menu prompts for simple operation; TPμp-40 panel-mounted thermal printer.

8. Power Supply: AC 220 V ± 10%; 50 Hz

9. Operating Conditions: Ambient temperature: 0°C to +40°C; Relative humidity: ≤90%

10. Dimensions / Weight: 370 × 370 × 220 mm / 16 kg

During measurement, this instrument displays the measured capacitance or inductance value, as well as other parameters such as voltage, current, power, frequency, impedance, and phase angle, facilitating a more comprehensive analysis of the test specimen’s condition.