MCJB-1600 Microcomputer-Based Comprehensive Relay Tester

Model: MCJB-1600 Quantity: 1 set Manufacturer: Hubei MECI Electric Power Equipment Co., Ltd

Category: Relay Protection Tester

Keywords: MCJB-1600 Microcomputer-Based Comprehensive Relay Tester

Product Overview

Product Features

The main features of the microcomputer-based relay protection tester are as follows:

  • Equipped with the user-friendly Windows XP operating system, the human-machine interface is intuitive and easy to use, enabling quick and efficient operation. To further enhance user convenience, a wide range of keyboard shortcuts have been defined, allowing users to perform tasks with a single key press.
  • High-performance embedded industrial control computers paired with large, high-resolution color TFT LCD displays provide rich, intuitive information, including the equipment’s current operating status, prompts for the next step, and various help messages.
  • Equipped with an ultra-thin industrial keyboard and a touch-enabled mouse, it allows users to perform various operations via the keyboard or mouse just as they would on a standard PC.
  • Equipped with an external USB interface, it enables convenient data access and software maintenance.
  • All test items can be completed without the need for any external equipment; test data are automatically displayed and recorded, and vector diagrams and characteristic curves are generated.
  • A high-performance D/A converter is employed, delivering waveforms with high accuracy and excellent linearity, as well as superior transient response and amplitude-frequency characteristics. Waveform accuracy and other performance metrics are consistently maintained across the entire measurement range.
  • It can directly output AC voltage, AC current, DC voltage, and DC current, with adjustable amplitude, phase angle, and frequency.
  • The power amplification stage employs a new high-power, high-fidelity linear amplifier circuit, delivering substantial output power with minimal ripple and interference. Even at maximum output current, the waveform remains undistorted and free of clipping.
  • The digital input interface can automatically accommodate both passive (dry-contact) and active inputs, and can also automatically adapt to the polarity of active inputs, operating reliably within an input voltage range of ±250 V.
  • It can perform a wide range of complex verification tasks, conveniently test and scan various protection settings, store test data in real time, display vector diagrams, print reports, and more.
  • It features a meticulously engineered chassis design that is compact, offers excellent heat dissipation, is lightweight, easy to carry, and facilitates convenient flow testing.
  • The instrument features self-protection functionality, a well-designed thermal management system, robust and comprehensive protection measures, soft-start power supply, as well as built-in fault self-diagnosis and interlock capabilities.

 

 

Technical Specifications

AC current source

  • Current source with a shared neutral point for six phases, with current rise and fall times < 100 μs.
  • Maximum output power: 350 VA per phase
  • Output accuracy:
Accuracy from 0.1 A to 1 A ±5 mA
Accuracy from 1A to 10A ±0.1%
Accuracy from 10A to 30A

±0.2%

  • Resolution:

 

0.1 A to 10 A resolution 1mA
Resolution from 10 A to 30 A

5mA

  • Single-phase continuous output time:

 

Output time: 0.1 A to 10 A No time limit
Output time for 10A to 20A ≥60 seconds
Output time for 20A to 30A ≥15 seconds

 

AC voltage source

  • Voltage source with six phases sharing a common neutral point, with current rise and fall times < 100 μs.
  • Maximum output power: ≥75 VA per phase
  • Output accuracy:
Accuracy from 1V to 5V ±5 mV
Accuracy from 5V to 125V

±0.1%

  • Resolution:

 

1V to 5V resolution 1mV
5V to 125V resolution 5mV

 

DC current source

  • Single-phase output range: -10 A to +10 A or 0 to 20 A
  • Maximum output power: 200 VA per phase
  • Output accuracy:
Accuracy of ±0.1 A to ±2 A ±10 mA
Accuracy of ±2 A to ±10 A

±0.2%

  • Resolution: 5 mA

 

 

Current Voltage Source

  • DC voltage output range: -150 V to +150 V or 0 to 300 V
  • Maximum output power: ≥100 VA
  • Output accuracy:
Accuracy from ±1 V to ±5 V ±20 mV
Accuracy from ±5 V to ±150 V

±0.2%

  • Resolution:
Resolution of ±1 V to ±5 V 5mV
Resolution: ±5 V to ±150 V 10mV

 

AC voltage and current source angle

  • Phase angle range: 0° to 360°
  • Accuracy: ±0.1°
  • Resolution: 0.01°

 

AC voltage and current source frequency

  • Frequency range: 10–1500 Hz
  • Output accuracy:
10 Hz to 65 Hz ±0.001 Hz
65 Hz to 1500 Hz ±0.02 Hz
  • Resolution: 0.001 Hz
  • Can superimpose harmonics of arbitrary amplitude and DC components from 2 to 20 times.

 

Timing accuracy

1 ms to 1 s ±1 ms
1S~999999S ±0.2%


Input quantity

  • Eight independent switch contact inputs with automatic polarity detection for powered contacts.
  • Compatible with dry contacts and 15V–250V powered contacts.

 

Output volume

  • Four pairs of programmable switch dry-contact outputs
  • Contact rating: 250 VDC, 0.5 A or 250 VAC, 0.5 A

 

Synchronicity

Voltage-current synchronization ≤10 μs

 

Power supply

  • AC Input Voltage

Rated value: 220V ± 10%

Reference value: 220 V ± 2%

  • AC power supply frequency:

Rated value: 50 Hz ± 10%

Reference value: 50 Hz ± 2%

 

Operating Environment Conditions

  • Ambient temperature: -10°C to +40°C
  • Relative humidity: ≤90%
  • Atmospheric pressure: 80–110 kPa

Related Products

New Product Recommendations

Product Center

Power Quality, Harmonic Analyzer

Metrological verification device

Relay Protection Tester

Transformer Testing

Capacitors and Generators

Product Inquiry

Leave your contact information to receive a free product quote.